Order Now $245.77

Compare the Lite Silver
Pulser to the SP5
Silver Pulser Here
View specifications of the
Silver Pulser Lite Here
Order Now $245.77


Three year Parts and labor warranty
Call for information on
ordering (479)-595-0460
The Silver Pulser is a dual function
unit 1. Bio-Stimulator
Click Here for more information on the Beck Protocol and 2. Ionic/Colloidal Silver Generator
with Constant-Current.
The Silver Pulser generates the
finest quality Ionic Colloidal Silver at a rate of 5-8 ppm
(part per million) in 2 Hours for 16 ounces of distilled water,
with an Ionic Colloid silver particle size that is mostly ions, with
colloidal particles in the range of 0.005 - 0.015 microns (Verified
on a Scanning Electron Microscope). The SP5 Silver Pulser (ZBB5) Model has a built-in
Constant-Current Circuit for the ultimate in Ionic/Colloidal Silver
Production. The Silver Pulser has two
attachments: one is to make ionic/colloidal silver and the other is for
bio-stimulation.
What is "The Silver Pulser"?
New Model SP5 Silver Pulser (ZBB5) features include:
See Picture Here
New
streamlined unit.
Built-in
Constant-Current Circuit for the Ionic/Colloidal Silver Output.
Yellow
LED Light indicates when the current through the stimulator electrodes
is correct and functioning.
Special
DIN style jack to comply with new government regulations.
Soft
carrying case
Each Silver Pulser is a professionally
designed quality unit, thoroughly tested on an oscilloscope, and is
guaranteed to operate per the specifications. (Click
HERE to see or the improved
schematic. NOTE: Our Silver Pulser has a
more advanced and proprietary circuit than what is shown here.)
The Silver Pulser is a dual
function unit 1) Bio-Stimulator and 2) Ionic/Colloidal Silver
Generator with Constant-Current.
The Silver Pulser uses only the
highest quality .9999
Pure Fine Silver Electrodes. Our
Assay Certificate for Silver Electrodes is on file, and can be viewed by
clicking HERE. Our
Certificate of Compliance for
Silver Electrode Purity is on file, and can be viewed by clicking
HERE.
The Silver Pulser generates the
finest quality Ionic Colloidal Silver at a rate of 5-8 ppm
(part per million) in 2 Hours for 16 ounces of distilled water,
with an Ionic Colloid silver particle size that is mostly ions, with
colloidal particles in the range of 0.005 - 0.015 microns (Verified
on a Scanning Electron Microscope). The SP5 Silver Pulser (ZBB5) Model has a built-in
Constant-Current Circuit for the ultimate in Ionic/Colloidal Silver
Production.
To
see independent lab tested results of our Ionic Colloidal Silver as
an anti-bacterial solution please click
HERE.
The Silver Pulser has a Bi-Phasic output frequency of ~3.92 Hertz
(cycles per second) at a nominal voltage of 31 VOLTS DC peak per
cycle.

Unique Features:
 |
The Bio-Electric
Protocol has changed. We boosted the output voltage
from 27 Volts to 31 Volts (from 54 Volts Peak-Peak, to 62 Volts
Peak-Peak). A new intensity control was specified to help widen the band
of the output control to avoid "bunching" the signal near the high end
of the control knob. |
 |
A unique circuit design allows
The Silver Pulser to operate from a single 9 Volt alkaline
battery. Original plans actually called for the use of 7 batteries in
the design. Our state-of-the-art electronic design utilizes a
proprietary DC-DC converter which boosts the output of the
9 Volt battery to the 31 Volts DC required by The Silver
Pulser. |
 |
Constant-Voltage Output - Unique
circuitry maintains the required 31 Volts output regardless
of battery voltage or other input power (like from an AC-DC Wall
Adaptor, Automobile Battery, or Solar Panel). Thus, as the battery runs
down or if the input voltage fluctuates, the output will maintain
the 31 Volts. No other unit using either 3 x 9 Volt batteries
or voltage triplers can offer this very important feature.
|
 |
We use only the purest, Fine Silver rod Wire
Electrodes, 4 Nine Grade (.9999
pure) for the Ionic-Colloid Silver production. |
 |
Constant-Current
Output - SP5 Silver Pulser (ZBB5) Model has built-in Constant-Current Circuit for
Ionic/Colloidal Silver production. |
 |
Output monitoring circuit and indicator. |
 |
The Bio-Stimulator Probes are of the
highest quality. |
 |
Our Electrical Circuit Boards are
GOLD Plated for extreme reliability and workmanship. |
 |
All electrical wire connections made
with Food Grade solders and fluxes for the highest in safety and
purity. |
 |
3 Year Parts and Labour Warranty
on all internally mounted components. Replacement Fine Silver
Electrodes and Probes are available. |
-
The Silver Pulser is housed in an
attractive new custom plastic enclosure with a built-in compartment for
the 9 Volt battery. A slide-off lid allows you to change the battery
easily. A Thumbwheel Switch Control Knob turns The Silver Pulser
on and off and varies the intensity of the "Bio-Stimulator Probe"
output.
A Green LED Light comes on when
the Silver Pulser is turned on.
A flashing Yellow LED light on the
unit indicates there is a correct Bio-Stimulator output and
comes on only when current is flowing.
An Orange LED light is used for
the Ionic-Colloidal Silver generation. The Orange LED
Light comes on only when current through Silver electrodes is correct and
the circuit is complete.
A Red LED Light indicates low
battery.
The Silver Pulser has one 6 pin DIN style jack for plugging in
the Fine Silver Electrodes and for the Bio-Stimulator Probes. A second
jack is used for hooking up an AC-DC Wall Adaptor so you don't
have to go through batteries. NOTE: You
cannot power the unit with a Wall Adaptor at the same time as using the
Bio-Stimulator output. This is a government regulatory stipulation.
However, a Wall Adaptor can be used for Silver production only.
We include Cotton Sleeves to put
over the Bio-Stimulator Probes for helping to maintain a good
connection when moistened. (Hint: Use a Salt Water solution or a
conductive gel for better conductivity!)
The Silver Pulser is packaged in a custom soft carrying case for
easy storage.
Electronics:
The Silver Pulser is designed to the
highest standards. We have improved on the design with added features. Our
electronic design is unique and efficient making the unit very portable and
light-weight. There's even a provision for adding an external power source
to save on batteries when making Ionic/Colloidal Silver, such as an AC-DC
Wall Adaptor which you can purchase from any electronic store.
Specifications:
 |
Battery Voltage: 9 Volts DC
(Alkaline Battery) |
 |
Optional Input Voltage: 6 - 12 Volts
DC @500mA Wall Transformer/Adapter, Automobile Battery, or
Solar Panel. |
 |
Output Voltage at Colloidal Silver
Electrodes: 31 Volts DC, (+/- 1 Volt)
Constant-Voltage Output
|
 |
Output Current at Colloidal Silver
rod Wires: 1.5 milliamps (+/- 0.5ma)
Constant-Current Output
|
 |
Ionic-Colloid Silver Production: 5 -
8ppm (parts per million) for 2 hours for 16 ounces
distilled water. |
 |
Ionic-Colloid Silver Particle Size:
Mostly ionic, with colloidal particles in the range of 0.005 - 0.015
microns when made as directed. |
 |
Ionic-Colloid Silver Colour: Clear or
Pale Gold. |
 |
Silver Electrodes Life: Can make many
gallons ionic/colloidal silver per set of Fine Silver
Electrodes, when
made as directed. |
 |
Output Voltage at Stimulator Probes:
31 Volts (Peak per Cycle, 62 Volts Peak-Peak) Bi-Phasic at
~3.92 Hertz (cycles per second) +/- 1 Hz. To see the actual
output waveform from the oscilloscope, please click
HERE. Note the extremely square and symmetrical waveform; free of
any spikes or artifacts. |
 |
Output Current at Stimulator Probes:
~12 milliamps maximum when probes shorted and Control Knob on
full intensity. |
 |
Operating Instructions
|
 |
Two (2)
.9999 silver rod (4 Nine Grade) Pure Fine Silver Wire Electrodes
|
 |
One (1)
Silver
Wire Electrodes Holder |
 |
One (1) High Grade
Plated Bio-Stimulator Probes |
 |
Two (2) VelcroŽ/NeopreneŽ Straps
|
 |
One (1) VelcroŽ Arm Strap
|
 |
One (1) ScotchbriteŽ scrubber pad
|
 |
One (1) 2 oz. Dark Glass Dropper Bottle
|
 |
Six (6) Cotton Probe Sleeves
|
 |
One (1) 9 Volt Alkaline Battery
|
 |
One (1) Soft Carrying Case
|
 |
CE Certification
|
 |
3 Year Parts and Labor Warranty
on internally mounted components |